Rivelatore magnetico HCDX-Y1 del difetto della particella magnetica dell'apparecchiatura di collaudo del giogo elettromagnetico magna pratico pratico del giogo |
|
Dettagli:
|
Nome prodotto: | Detettore di difetti di particelle magnetiche mobili | AC Currente magnetizzante (AC): 0 ~ 1500A (True RMS): | 0 ~ 1500a (True RMS) |
---|---|---|---|
Demagnetizzazione: | (AC) 1500 ~ 0A (HWDC) da 1500 a 0A | Tensione di ingresso: | 380V 50Hz |
Evidenziare: | portable magnetic flaw detector,magnetic particle testing equipment,movable magnetic particles tester |
Movable Magnetic Particles Flaw Detector
The HCDX 1500 mobile magnetic particle flaw detector can magnetizeparts in AC (or half wave DC magnetization HWDC). And with automatic demagnetization function, no additional demagnetization device is required.
8 bit MCU is adopted as the controller by this magnetic particles flaw detector, and the continuous regulation of magnetizing current can be realized through the precise collection of the AC zero voltage crossing signal and the signal of current regulation. It has the function of
maximum current limit. With the function of phase controlled, the detector is suitable for both continuous technique and residual technique.
The current value is displayed on the analog ammeter or digital ammeter. The prod sets and trigger button are for operating in the narrow space.
The output current is reduced from the initial value to zero automatically when demagnetizing. Non contact swit ch is adopted for the equipment.
This detector can be connected to the prod sets (handheld electrode sets) or spiral cable (flexible coil). Also there are some coils or electrodes designed for this equipment to become a simple inspection machine tool as op tion.
Technical parameters:
AC magnetizing current (AC) | 0 ~ 1500A (true RMS) |
Half wave DC magnetizing current (HWDC) | 0 ~ 1500A (2 times the average) |
Demagnetization | (AC) 1500 ~ 0A (HWDC) 1500 to 0A |
Temporary load rate | ≤30% |
Demagnetization time | < 5s |
Input voltage | 380V 50Hz |
Main functions:
Detection methods: support rod method, winding method, coil method
Magnetization method: AC magnetization, DC magnetization (HWDC),
pulse magnetization
Demagnetization method: AC demagnetization using far away met
hod
demagnetization (attenuation method), AC demagnetization using
ultra low frequency demagnetization
Standard configuration:
Mobile host 1
Support rod probe 1 set
robe cable 1
Foot switch 1
Optional accessories
Fixed coil
Wound cable
Persona di contatto: Ms. Shifen Yuan
Telefono: 8610 82921131,8618610328618
Fax: 86-10-82916893